High Quality ACSR Conductor (ASTM B232) for Sale

Model NO.: ASTM B232
Brand: Henan Jiapu Cable
Cross Section Area: <1250mm2
Conductor Type: Aluminium
Structure: Stranded
Material: Aluminiun 1350
Voltage Rating: From Extra High Voltage to Utilization Voltages on
No.of Wire: 1-91
Trademark: Jiapu
Transport Package: Wooden Drums
Specification: ACSR
Origin: Henan China
HS Code: 7614100000
Model NO.: ASTM B232
Brand: Henan Jiapu Cable
Cross Section Area: <1250mm2
Conductor Type: Aluminium
Structure: Stranded
Material: Aluminiun 1350
Voltage Rating: From Extra High Voltage to Utilization Voltages on
No.of Wire: 1-91
Trademark: Jiapu
Transport Package: Wooden Drums
Specification: ACSR
Origin: Henan China
HS Code: 7614100000
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

 Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)


 Relative manufacturing standards:
IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.


All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.


Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Packing:
Standard export wooden drums
Standards IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110
Certificate ISO 9001 and ISO 14001. CE ,SONCAP
Type AAC, AAAC, ACSR, AACSR&ACAR conductor
AAC AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
AAAC (AAAC) Conductor as per ASTM-B-399-1992
ACSR ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)


Application
The conductors are suitable for use in spans on wood poles, transmission towers,and other structures where tensile strength and temperature ratings are not required. Application range from extra high voltage(EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises. AAC(All aluminum conductor) is the most economical bare overhead conductor due to its lighter weight. It offers easier handing during installation and use of simpler fittings. The conductor is corrosion resistant due to its homogeneous construction.
 

Property:
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers.
  

Standard:
  
ASTM B230,B231,B400 Standard

Code word

Size of
Conductor

Stranding and Wire Diameter

Overall Diameter

Max.D.C. Resistance at 20°C

Code word

Size of Conductor

Stranding and Wire Diameter

Overall Diameter

Max.D.C. Resistance at 20°C

AWG or MCM

mm

mm

ohm/km

AWG or MCM

mm

mm

ohm/km

Peachbell

6

7/1.554

4.67

2.1692

Verbena

700

37/3.493

24.45

0.0813

Rose

4

7/1.961

5.89

1.3624

Nasturtium

715.5

61/2.75

24.76

0.0795

Lris

2

7/2.474

7.42

0.8577

Violet

715.5

37/3.533

24.74

0.0795

Pansey

1

7/2.776

8.33

0.6801

Cattail

750

61/2.817

25.35

0.0759

Poppy

1/0

7/3.119

9.36

0.5390

Petunia

750

37/3.617

25.32

0.0759

Aster

2/0

7/3.503

10.51

0.4276

Lilac

795

61/2.90

26.11

0.0715

Phlox

3/0

7/3.932

11.80

0.3390

Arbutus

795

37/3.724

26.06

0.0715

Oxlip

4/0

7/4.417

13.26

0.2688

Snapdragon

900

61/3.086

27.78

0.0632

Valerian

250

19/2.913

14.57

0.2275

Cockscomb

900

37/3.962

27.73

0.0632

Sneezewort

250

7/4.80

14.4

0.2275

Goldenrod

954

61/3.177

28.6

0.0596

Laurel

266.8

19/3.01

15.05

0.2133

Magnolia

954

37/4.079

28.55

0.0596

Daisy

266.8

7/4.96

14.9

0.2133

Camellia

1000

61/3.251

29.36

0.0569

Peony

300

19/3.193

15.97

0.1896

Hawkweed

1000

37/4.176

29.23

0.0569

Tulip

336.4

19/3.381

16.91

0.1691

Larkspur

1033.5

61/3.307

29.76

0.0550

Daffodil

350

19/3.447

17.24

0.1625

Bluebell

1033.5

37/4.244

29.72

0.0550

Canna

397.5

19/3.673

18.36

0.1431

Marigold

1113

61/3.432

30.89

0.0511

Goldentuft

450

19/3.909

19.55

0.1264

Hawthorn

1192.5

61/3.551

31.05

0.0477

Syringa

477

37/2.882

20.19

0.1193

Narcissus

1272

61/3.668

33.02

0.0477

Cosmos

477

19/4.023

20.12

0.1193

Columbine

1351.5

61/3.78

34.01

0.0421

Hyacinth

500

37/2.951

20.65

0.1138

Carnation

1431

61/3.89

35.03

0.0398

Zinnia

500

19/4.12

20.6

0.1138

Gladiolus

1510.5

61/4.00

35.09

0.0376

Dahlia

556.5

19/4.346

21.73

0.1022

Coreopsis

1590

61/4.099

36.51

0.03568

Mistletoe

556.5

37/3.114

21.79

0.1022

Jessamine

1750

61/4.302

38.72

0.0325

Meadowsweet

600

37/3.233

22.63

0.0948

Cowslip

2000

91/3.76

41.40

0.02866

Orchid

636

37/3.33

23.31

0.0894

Lupine

2500

91/4.21

46.30

0.0230

Heuchera

650

37/3.366

23.56

0.0875

Trillium

3000

127/3.90

50.75

0.0192

Flag

700

61/2.72

24.48

0.0813

Bluebonnet

3500

127/4.21

54.80

0.01653
 



Workshop:
High Quality ACSR Conductor (ASTM B232) for Sale


Shipment:
High Quality ACSR Conductor (ASTM B232) for Sale


 
Customer:
High Quality ACSR Conductor (ASTM B232) for Sale


 
Certification:
High Quality ACSR Conductor (ASTM B232) for Sale



 
FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS

4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables. 

8. Do you supply the customers with installation service in foreign country ?
We don't have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
  
  AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

 Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)


 Relative manufacturing standards:
IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.


All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.


Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Packing:
Standard export wooden drums
Standards IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110
Certificate ISO 9001 and ISO 14001. CE ,SONCAP
Type AAC, AAAC, ACSR, AACSR&ACAR conductor
AAC AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
AAAC (AAAC) Conductor as per ASTM-B-399-1992
ACSR ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)


Application
The conductors are suitable for use in spans on wood poles, transmission towers,and other structures where tensile strength and temperature ratings are not required. Application range from extra high voltage(EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises. AAC(All aluminum conductor) is the most economical bare overhead conductor due to its lighter weight. It offers easier handing during installation and use of simpler fittings. The conductor is corrosion resistant due to its homogeneous construction.
 

Property:
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers.
  

Standard:
  
ASTM B230,B231,B400 Standard

Code word

Size of
Conductor

Stranding and Wire Diameter

Overall Diameter

Max.D.C. Resistance at 20°C

Code word

Size of Conductor

Stranding and Wire Diameter

Overall Diameter

Max.D.C. Resistance at 20°C

AWG or MCM

mm

mm

ohm/km

AWG or MCM

mm

mm

ohm/km

Peachbell

6

7/1.554

4.67

2.1692

Verbena

700

37/3.493

24.45

0.0813

Rose

4

7/1.961

5.89

1.3624

Nasturtium

715.5

61/2.75

24.76

0.0795

Lris

2

7/2.474

7.42

0.8577

Violet

715.5

37/3.533

24.74

0.0795

Pansey

1

7/2.776

8.33

0.6801

Cattail

750

61/2.817

25.35

0.0759

Poppy

1/0

7/3.119

9.36

0.5390

Petunia

750

37/3.617

25.32

0.0759

Aster

2/0

7/3.503

10.51

0.4276

Lilac

795

61/2.90

26.11

0.0715

Phlox

3/0

7/3.932

11.80

0.3390

Arbutus

795

37/3.724

26.06

0.0715

Oxlip

4/0

7/4.417

13.26

0.2688

Snapdragon

900

61/3.086

27.78

0.0632

Valerian

250

19/2.913

14.57

0.2275

Cockscomb

900

37/3.962

27.73

0.0632

Sneezewort

250

7/4.80

14.4

0.2275

Goldenrod

954

61/3.177

28.6

0.0596

Laurel

266.8

19/3.01

15.05

0.2133

Magnolia

954

37/4.079

28.55

0.0596

Daisy

266.8

7/4.96

14.9

0.2133

Camellia

1000

61/3.251

29.36

0.0569

Peony

300

19/3.193

15.97

0.1896

Hawkweed

1000

37/4.176

29.23

0.0569

Tulip

336.4

19/3.381

16.91

0.1691

Larkspur

1033.5

61/3.307

29.76

0.0550

Daffodil

350

19/3.447

17.24

0.1625

Bluebell

1033.5

37/4.244

29.72

0.0550

Canna

397.5

19/3.673

18.36

0.1431

Marigold

1113

61/3.432

30.89

0.0511

Goldentuft

450

19/3.909

19.55

0.1264

Hawthorn

1192.5

61/3.551

31.05

0.0477

Syringa

477

37/2.882

20.19

0.1193

Narcissus

1272

61/3.668

33.02

0.0477

Cosmos

477

19/4.023

20.12

0.1193

Columbine

1351.5

61/3.78

34.01

0.0421

Hyacinth

500

37/2.951

20.65

0.1138

Carnation

1431

61/3.89

35.03

0.0398

Zinnia

500

19/4.12

20.6

0.1138

Gladiolus

1510.5

61/4.00

35.09

0.0376

Dahlia

556.5

19/4.346

21.73

0.1022

Coreopsis

1590

61/4.099

36.51

0.03568

Mistletoe

556.5

37/3.114

21.79

0.1022

Jessamine

1750

61/4.302

38.72

0.0325

Meadowsweet

600

37/3.233

22.63

0.0948

Cowslip

2000

91/3.76

41.40

0.02866

Orchid

636

37/3.33

23.31

0.0894

Lupine

2500

91/4.21

46.30

0.0230

Heuchera

650

37/3.366

23.56

0.0875

Trillium

3000

127/3.90

50.75

0.0192

Flag

700

61/2.72

24.48

0.0813

Bluebonnet

3500

127/4.21

54.80

0.01653
 



Workshop:
High Quality ACSR Conductor (ASTM B232) for Sale


Shipment:
High Quality ACSR Conductor (ASTM B232) for Sale


 
Customer:
High Quality ACSR Conductor (ASTM B232) for Sale


 
Certification:
High Quality ACSR Conductor (ASTM B232) for Sale



 
FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cabl

8 Inches Tablet PC

The 8-inch tablet will have a big impact on the 7-inch and 10-inch tablet market. Because the portability of an 8-inch tablet is stronger than that of a 10-inch tablet, and the usable area is larger than that of a 7-inch tablet. The most important thing is that the price is more moderate, which is much cheaper than a 10-inch tablet. It can be said that the 8-inch tablet computer has a good balance between portability and screen display area, and is more likely to be favored by the majority of users.


8 Inches Tablet Pc,Tablet Computer,8 Inch Android Tablets,8 Inch Tablet

Jingjiang Gisen Technology Co.,Ltd , https://www.jsgisentec.com