Medium Voltage Pole Mounted Circuit Breaker

Model NO.: FAR
Poles Number: 3
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification: VDE, ISO9001-2000, Type Tested
Product Name: Outdoor Pole Mounted Auto Circuit Recloser 24kv
Mechanism Life: 10000 Times
Rated Current: 630A Auto Recloser
Port: Ningbo/Shanghai
Rated Voltage: 24kv
Payment: Tt / LC
Trademark: FARADY
Transport Package: Wooden Case
Specification: IEC56, IEC62271-100, GB1984, DL402(ANSI C37)
Origin: Zhejiang, China
HS Code: 8535900090
Model NO.: FAR
Poles Number: 3
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification: VDE, ISO9001-2000, Type Tested
Product Name: Outdoor Pole Mounted Auto Circuit Recloser 24kv
Mechanism Life: 10000 Times
Rated Current: 630A Auto Recloser
Port: Ningbo/Shanghai
Rated Voltage: 24kv
Payment: Tt / LC
Trademark: FARADY
Transport Package: Wooden Case
Specification: IEC56, IEC62271-100, GB1984, DL402(ANSI C37)
Origin: Zhejiang, China
HS Code: 8535900090

++++General
Farady Powertech strives to bring our customers the latest technology and competitive pricing and best service for pole mounted Auto circuit recloser
The FAR series Auto circuit recloser can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. And its rated current can reach 1600A.
The FAR series Auto circuit recloser integrates the functions of control, protection, measurement,communication,fault detection,on-line monitoring of closing or opening.comply to  IEC62271 and ANSI/IEEE C37.60 standard
++++Service environment
a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m or more higher.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
++++Technical data
 

No. Item Unit data
1 Rated voltage kV 15 27 38
2 Rated current A 630 1250 1600
3 Rated frequency HZ 50/60
4 Power frequency 1min Dry kV 50 65 85
Wet 45 55 75
5 Lightning impulse withstand voltage(peak value)alternate, opposite/fracture kV 110 150 170
6 Rated short circuit breaking current kA 20 16/25 12.5
7 Rated short current switching current(peak value) kA 50 40/63 31.5
8 Rated peak value withstand current kA 50 40/63 31.5
9 4S short time withstand current kA 20 16/25 12.5
10 Rated operating circulate   O-T1-CO-T2-CO-T3-CO-T4-CO
11 Breaking current frequency under rated short circuit times 30
12 Mechanism life times 10000
13 Secondary loop 1 min power frequency withstand voltage kV 2

++++Outline & Sizes for FAR
Medium Voltage Pole Mounted Circuit Breaker
Medium Voltage Pole Mounted Circuit Breaker

++++General
Farady Powertech strives to bring our customers the latest technology and competitive pricing and best service for pole mounted Auto circuit recloser
The FAR series Auto circuit recloser can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. And its rated current can reach 1600A.
The FAR series Auto circuit recloser integrates the functions of control, protection, measurement,communication,fault detection,on-line monitoring of closing or opening.comply to  IEC62271 and ANSI/IEEE C37.60 standard
++++Service environment
a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m or more higher.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
++++Technical data
 

No. Item Unit data
1 Rated voltage kV 15 27 38
2 Rated current A 630 1250 1600
3 Rated frequency HZ 50/60
4 Power frequency 1min Dry kV 50 65 85
Wet 45 55 75
5 Lightning impulse withstand voltage(peak value)alternate, opposite/fracture kV 110 150 170
6 Rated short circuit breaking current kA 20 16/25 12.5
7 Rated short current switching current(peak value) kA 50 40/63 31.5
8 Rated peak value withstand current kA 50 40/63 31.5
9 4S short time withstand current kA 20 16/25 12.5
10 Rated operating circulate   O-T1-CO-T2-CO-T3-CO-T4-CO
11 Breaking current frequency under rated short circuit times 30
12 Mechanism life times 10000
13 Secondary loop 1 min power frequency withstand voltage kV 2

++++Outline & Sizes for FAR
Medium Voltage Pole Mounted Circuit Breaker
Medium Voltage Pole Mounted Circuit Breaker

Cummins Generator Set

Cummins Generator Set,Diesel Generator,Cummins Engine,Soundproof Generator

Yangzhou Hengyuan Electromechanical Equipment Co., Ltd. , https://www.lchypower.com