HuiZhou Superpower Technology Co.,Ltd. , https://www.spchargers.com
Applications
These heavy duty cables are designed for use on longwall shearers, where three shielded power conductors, three unshielded control conductors, and a grounding conductor are required.
Standards
ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96
Construction
Conductors: Stranded annealed tinned copper conductor.
Insulation: Ethylene Propylene Rubber (EPR).
Insulation Shield: Tinned copper/textile braid.
Ground Check Conductor: Tinned copper with a yellow insulation, located in the center of the cable.
Grounding Conductor: Tinned copper conductor, located in the center of the cable.
Jacket: Reinforced extra-heavy-duty Chlorinated Polyethylene (CPE), black.
Options
Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties
Minimum Bending Radius: 6×OD
Maximum Conductor Operating Temperature: +90ºC
Constructon
No. of Strands
Grounding Conductor Size
Control Conductor Size
Nominal Insulaton Thickness
Nominal Jacket Thickness
Nominal Overall Diameter
Nominal Weight
Ampacity
No. of cores×AWG/kcmil
AWG/kcmil
AWG/kcmil
inch
inch
inch
lbs/kf
A
3×2/0
323
5
16
0.11
0.22
2.2
3716
243
3×3/0
418
4
16
0.11
0.235
2.36
4130
279
3×4/0
532
3
16
0.11
0.235
2.5
5190
321
3×350
888
1
16
0.12
0.265
2.95
7571
435
Type SHD-PCG, Mining Cable, Cu/Epr/CPE, 3/C, 5kv (ICEA S-75-381/NEMA WC-58)
Applications
These heavy duty cables are designed for use on longwall shearers, where three shielded power conductors, three unshielded control conductors, and a grounding conductor are required.
Standards
ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96
Construction
Conductors: Stranded annealed tinned copper conductor.
Insulation: Ethylene Propylene Rubber (EPR).
Insulation Shield: Tinned copper/textile braid.
Ground Check Conductor: Tinned copper with a yellow insulation, located in the center of the cable.
Grounding Conductor: Tinned copper conductor, located in the center of the cable.
Jacket: Reinforced extra-heavy-duty Chlorinated Polyethylene (CPE), black.
Options
Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties
Minimum Bending Radius: 6×OD
Maximum Conductor Operating Temperature: +90ºC
Constructon
No. of Strands
Grounding Conductor Size
Control Conductor Size
Nominal Insulaton Thickness
Nominal Jacket Thickness
Nominal Overall Diameter
Nominal Weight
Ampacity
No. of cores×AWG/kcmil
AWG/kcmil
AWG/kcmil
inch
inch
inch
lbs/kf
A
3×2/0
323
5
16
0.11
0.22
2.2
3716
243
3×3/0
418
4
16
0.11
0.235
2.36
4130
279
3×4/0
532
3
16
0.11
0.235
2.5
5190
321
3×350
888
1
16
0.12
0.265
2.95
7571
435
Type Shd-Cgc, Mining Cable, Cu/Epr/CPE, 3/C, 5kv (ICEA S-75-381/NEMA WC-58)
Model NO.: Type SHD-CGC
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 5 Kv
Size: 2/0-350 AWG or Mcm
Number of Cores: 3
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
Model NO.: Type SHD-CGC
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 5 Kv
Size: 2/0-350 AWG or Mcm
Number of Cores: 3
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
Type SHD-PCG, Mining Cable, Cu/Epr/CPE, 3/C, 5kv (ICEA S-75-381/NEMA WC-58)